- Test & Measurement
-
Analyzers
-
Oscilloscope
-
Meters
-
Generators
-
DC Power Supply
-
Optical Communications
-
Other Test Equipment
-
Accessories
-
Probes
-
Software
-
AC Power Sources
-
Accessory Kits
-
Amplifiers
-
Antenna
- View All Categories >>
-
- Semiconductor & PCB
-
Front End
-
Back End
-
PC Board Assembly
- View All Categories >>
-
- Surplus & Liquidation
- Computers & Electronics
- Construction
-
Aggregate Equipment
-
Air Compressors
-
Asphalt / Pavers / Concrete Equipment
-
Compactors
-
Cranes
-
Crawler Loaders
-
Dozers
-
Drills
-
Dumpers
-
Excavators
-
Forestry Equipment
-
Forklifts
-
Generator Sets
-
Lifts
- View All Categories >>
-
- Biotech & Life Sciences
-
Biotechnology
-
Cell Counters
-
DNA Sequencers
-
DNA Synthesizers
-
Densitometers
-
Electrophoresis
-
Electroporation
-
Fermenters / Bioreactors
-
Flow Cytometers
-
Gel Dryer
-
Hybridization Ovens/Incubators
-
Immunoassay Systems
-
Microarray Scanners
-
Microplate Dispensers
- View All Categories >>
-
- Machinery
-
Abrasives
-
Air Compressors
-
Air Cooling & Heating Equipment
-
Bar Machinery
-
Bending & Forming Equipment
-
Boring Mills
-
Broaching Machines & Keyseaters
-
CNC Machinery
-
Chemical & Processing Equipment
-
Chip, Recycling & Scrap Equipment
-
Cleaning, Painting & Washing Equipment
-
Coil Processing Equipment
-
Construction Equipment
-
Die Casting Machines
- View All Categories >>
-
- Commercial Trucks
-
Heavy Duty Trucks
-
Medium Duty Trucks
-
Light Duty Trucks
-
Trailers
- View All Categories >>
-
- Chemical Equipment
-
AGITATORS
-
AIR FIN COOLERS
-
BLENDERS
-
BLOW MOLDERS
-
BLOWERS
-
BOILERS
-
CENTRIFUGES
-
COLUMNS
-
COLUMNS DBL DIA
-
COMPLETE PLANTS
-
COMPRESSORS
-
CONVERTERS
-
CONVEYORS
-
COOLING TOWERS
- View All Categories >>
-
- Apparel and Textile
-
Textile Machinery
-
Apparel & Textile Machinery Parts
-
Apparel Machinery
-
Home Textile Product Machinery
-
Apparel Accessories Machinery
-
Leather Production Machinery
- View All Categories >>
-
- Medical Equipment
-
Beds, Stretchers and Furniture
-
Cardiology
-
Consumables and Supplies
-
Cosmetic
-
Defibrillator
-
Dental
-
EMS/Rescue
-
Endoscopy
-
Exam Room
-
Homecare/Rehab
-
Imaging
-
Laboratory
-
Monitors/ICU/CCU
-
Neonatal
- View All Categories >>
-
- Printing Equipment
-
Press
-
Prepress
-
Postpress
-
Guillotines
-
Packaging
-
Misc
-
Flexo Printing
-
Web offset
-
Screen Printing
-
Package deals
-
Spare Parts
- View All Categories >>
-
- Packaging Equipment
-
Accumulators
-
Bag Dumps
-
Bag Sealers
-
Bagging Machines
-
Blister Packaging Lines
-
Blister Packers
-
Blister Sealers
-
Blow Fill Seal
-
Bottle Rinsers
-
Canning Equipment
-
Cap Sorters
-
Cappers
-
Cartoners
-
Case Erectors
- View All Categories >>
-
Keeping the 'Class' in Classifying Tanks
04/01/2013 21:55:14
Sand classifying tanks have been used for more than 50 years for refining glacial/alluvial ‘natural’ and ‘manufactured’ sands and sand slurries. They have been used primarily in North America for three typical reasons:
Concentrating or ‘scalping’ water in a low-percent solids slurry for more efficient dewatering by downstream equipment;
Removal of excess intermediate sand grain sizes to produce a uniformly graded product for many common construction sand specifications; and
The production of two controlled and one uncontrolled sand product from a single feed.
As with any process equipment, periodic operational and maintenance checks are recommended to optimize a machine’s operation. Your manufacturer’s installation and maintenance manual can be used as a guide to allow the most efficient performance and yield of desired sand products.
Operation
This type of sand tank is not a ‘set it once and walk away’ device, as sand feeds can vary due to changing pit feeds or the performance of crushers and other equipment that may precede it.
Periodic sampling of the sand discharging from the sand tank valves, particularly at the first two or three stations, is recommended to make sure that the product is mostly coarse sand particles. If a specification concrete sand gradation is found in the product valve sampling, adjustments to the rising current water injection and tank overflow weirs should be made to move finer sand particles further down the sand tank. This provides a more controlled blending of coarse, intermediate, and fine sands being made by the PLC control system.
During a non-operational period, an empty sand tank’s operating system should be inspected to assure that the valves at each station are opening and closing as programmed by the controller. This would include stalling the torque motor paddle at each valve station.
To assure fine product-sized sand retention, make sure that all weirs are level, allowing uniform depth of silt slurry overflow.
Maintenance
To minimize downtime during peak production, periodic inspections of key components should be made.
All sands cause wear on components to varying degrees. Valves and valve seats are among the most commonly replaced items. While some original components are hard cast-iron alloys intended for abrasion resistance, these parts are often replaced by polyurethane components, which offer extended wear life in most instances.
Valve rods, torque motor paddles, and paddle rods should be periodically inspected for wear and replaced when needed.
Sand discharging from the valves exits the sand tank via down pipes, often equipped with elbows, to a sectionalized collecting flume. These elbows handling coarse sand experience extensive wear and require more frequent replacement than valves discharging finer sand. While many sand tanks have used steel pipes and hard iron elbows, these metal components have been replaced with thick walled PVC pipes and polyurethane elbows that are easier to handle, quicker to replace, and provide equal or extended performance.
Flume liners in the sloping two- or three-cell compartment trough need to be visually inspected and replaced as needed.
Types of liners include AR steels, rubber, and polyurethane and should cover not only the bottom of the flume, but also the sides to provide protection to these cell compartments of classified sands.
The opening of the sand tank valves is typically made possible by a hydraulic power unit with dedicated lines connecting hydraulic cylinders attached to each valve rod. Periodic replacement of the hydraulic fluid and filter, as specified by the manufacturer’s manual, should be followed.
For sand tanks that are not operational during a seasonal shut-down period, even if not changing the fluid, the hydraulic reservoir should be checked for water that may have accumulated from temperature-caused condensation. The water should be drained from the reservoir and the proper hydraulic fluid level maintained as recommended by the manufacturer.
All electric systems, wiring, and hydraulic lines should be checked periodically to make sure all are functioning properly and do not cause an improper grounding or leakage causing a hazard to maintenance personnel. The control enclosure on top of the sand tank housing the hydraulic cylinders, torque motors, solenoid valves, and associated electrical wiring and hydraulic lines should be cleared of any accumulated sand to assure no interference that can cause component failure.
If a sand tank is equipped with a rising-current recirculating-pump system, the impeller should be checked for wear and replaced when worn. V-belts driving the pump and bearing lubricant should be inspected and maintained as specified by the manufacturer’s manual.
Sand classifying tanks, while from an initial overview may seem complex, can be easily maintained with periodic inspections and repairs providing higher value sand products.