W&F OLT-50 Optical Loss Tester Set by Beijing W&F Technology Co., Ltd
- Item Condition:
- Brand:
- Model#:
- Location:
- Price:
Product Description
Specifications
ORL test1.Pass/Fail assessment
2. Bidirectional loss test on single fiber
3.Optical power monitoring
4.SLS + OPM + OLT +
OLT-50 Optical Loss Tester Set
OLT-50 Intelligent Optical Loss Tester is an all-in-one loss tester integrated with Stabilized Laser Source, Optical Power Meter, Optical Loss Tester, ORL Tester and Length Testing functions. It can perform automatic bidirectional loss test on single fiber with Pass/Fail assessment. With rich functions, flexible configuration and excellent user friendly design, OLT-50 is the ideal optical loss tester to completely evaluate the optical fiber link condition in FTTx, LAN and CATV network.
Automatic Bidirectional Loss Test on Single Fiber
Two OLT-50 at both ends of a single optical fiber can perform bidirectional loss test by just pressing one button and can automatically measure and display the entire fiber attenuation to help users acquire complete and accurate optical fiber loss information.
Specifications
Wavelength (±20nm) | 1310/1550nm | 1310/1490/1550nm | 1310/1550/1625nm | ||
Spectrum Width | ≤5nm | ||||
Emitter Type | FP-LD | ||||
Output Power | >-4dBm | ||||
Power Stability | ±0.05dB/15min; ±0.10dB/8hr | ||||
Output Mode | CW, 270Hz, 1KHz, 2KHz | ||||
Optical Power Meter | |||||
Calibrated Wavelength | 850, 1300, 1310, 1490, 1550, 1625nm | ||||
Power Range (dBm) | -70 ~ +10 (-60 ~ +10@850nm) | -50 ~ +27 | |||
Display Unit | W/mW/μW/nW/pW/dBm/dB(REF) | ||||
Detector Type | InGaAs | ||||
Accuracy | ±5%±0.01nW (±0.5 dB@850nm) | ±5%±1nW (±0.5 dB@850nm) | |||
Resolution | 0.01dB | ||||
Auto Wavelength Identification | Yes (With ShinewayTech specified Stabilized Laser Source) | ||||
MOD Identification | 270Hz, 1KHz, 2KHz | ||||
Optical Loss Test | |||||
Link Loss Range | 50dB (1550nm, 200km) | ||||
Link Loss Accuracy | ±0.25dB | ||||
Link Loss Test Time | < 2 seconds per wavelength | ||||
ORL Test (Optional) | |||||
ORL Range | 0~60dB (APC connector) | ||||
ORL Accuracy | ±0.75dB@(0~50dB), ±1.5dB@(50~60dB) | ||||
ORL Uncertainty | ±0.5dB@20dB | ||||
General Specifications | |||||
Connector | FC (Interchangeable SC, ST) | ||||
Data Storage | 1000 records | ||||
Data Interface | USB | ||||
Backlight Display | Yes | ||||
Auto Off | Yes (Auto-off after 5 minutes idle) | ||||
Power Supply | Lithium Battery/ AC Adapter | ||||
Battery Life | Continuous operation ≥35 hours | ||||
Operating Temperature | -20°C ~ 50°C | ||||
Storage Temperature | -40°C ~ 70°C | ||||
Relative Humidity | 0 ~ 95% (Non-condensing) | ||||
Weight | 350g | ||||