Sorry, the search criteria can not be empty
Search

M9713B,0~500V/0~30A/600W battery test Programmable DC Electronic Load by Xiamen Wellzion Electronics Co., Ltd

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Xiamen Wellzion Electronics Co., Ltd
86-592-5562446


Contact the seller Add to Inquiry Cart

Product Description

Specifications

0~500V/0~30A/600W
RS232/RS485/USB
Battery testing and short-circuit function
Supporting external trigger input and output

Features and Benefits:

  • Six high speed operation modes: CC,CR,CV,CW,CC+CV,CR+CW

  • Over current, over voltage, over power, over heat, polarity reversed protection

  • High-luminance VFD screen with two lines& four channels display

  • Intelligent fan system fan will be automatically initiated according to the temperature

  • Soft start time setting, carrying the power supplier according to the voltage value set

  • Battery testing and short-circuit function

  • Available of dynamic testing and rising edge and falling edge setting

  • Supporting external trigger input and output

Application:

Production line(cell phone charger, cell phone battery, electric vehicle battery, switching power supplier, linear power supplier), research insititutes, automotive electronics, aeronautics and astronautics,ships, solar cells fule cell, etc.

Specifications
 
Input Rating
 
Power600W
Current0-30A
Voltage0-500V
CC ModeRange0-12A0-120A
Resolution1mA10mA
Accuracy0.05%+0.05%FS0.1%+0.05%FS
CV ModeRange0.1-19.999V0.1-150V
Resolution1mV10mV
Accuracy0.03%+0.02%FS0.03%+0.02%FS
CR ModeRange0.03Ω -10K0.03Ω -5K
Resolution16 bit16 bit
Accuracy0.1%+0.1%FS0.1%+0.1%FS
CW ModeRange0-600W0-600W
Resolution1mW10mW
Accuracy0.1%+0.1%FS0.1%+0.1%FS
V MeasurementVoltage0-19.999V0-150V
Resolution1mV10mV
Accuracy0.015%+0.03%FS0.015%+0.03%FS
I MeasurementCurrent0-12A0-120A
Resolution0.1mA1mA
Accuracy0.05%+0.08%FS0.1%+0.08%FS
W MeasurementWatt100W600W
Resolution1mW10mW
Accuracy0.1%+0.1%FS0.1%+0.1%FS
Battery Measurement Battery Input: 0.5-120V; Max. Measurement: Capacity=999/H;   Resolution=0.1mA;   Time Range=1S-16HS
Dynamic Measurement Transition  List: 0-25kHZ; 2.5A/uS;   T1& T2: 60uS-999S;   Accuracy: + 15% offset+10% FS
CC soft-startup Time 1 mS; 2 mS; 5mS; 10mS; 20 mS; 50 mS; 100 mS; 200 mS    Accuracy: + 15% offset+10% FS
Short CircuitCurrent(CC)13.2A132A
Voltage(CV)0V
Resistance(CR)13mΩ
TemperatureOperating0— 40º C
Nonoperating– 10º C— 70º C
DimensionW*H*D(mm)428*103.5*453.5
Weightkg17.6


Item added to Inquiry Cart