Sorry, the search criteria can not be empty
Search

SA2100,power quality analyzer,portable power analyzer by Xiamen Wellzion Electronics Co., Ltd

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Xiamen Wellzion Electronics Co., Ltd
86-592-5562446


Contact the seller Add to Inquiry Cart

Product Description

Specifications

Safety: CAT III 1000V / CAT IV 600V
Single-phase 2 W/Single-phase 3 W/ 3-phase 3 W/ 3-phase 4 W
Support USB port and LAN port

Features and Benefits

  • Safety: CAT III 1000V / CAT IV 600V

  • Standards: IEC61000-4-30 (2008) S class, EN50160 (2007)

  • Easy operation to capture the power quality problem

  • Single-phase 2 W/Single-phase 3 W/ 3-phase 3 W/ 3-phase 4 W

  • Display: Run Chart, Bar Chart, Vector Graphic, Waveform, Event List, Readings.

  • 8G Memory Card to make the long-term measuring data storage

  • Support USB port to connect to PC and analyze the data/screen shots copied by U-disk

  • Support LAN port to make the remote control available, transfer the measuring data

Specifications

SpecificationsMeasurement RangeResolutionAccuracy
Voltage/Current/Frequency
Channel3-phase line input + 1 neutral line input
Vrms(dc+ac)1 ~ 1000Vrms0.1Vrms±5%
Vpk1 ~ 1400Vpk0.1Vpk±5%
V(CF)1.0 ~ >2.80.01±5%
Arms1~ 3000A1A±1% ± 5digits
1~ 300A0.1A±1% ± 5digits
Apk1 ~ 4000Apk1A±1% ± 5digits
A(CF)1 ~ 100.01±5%
Frequency42.5~57.5Hz(50Hz nominal)0.01Hz±0.01%
51~69Hz(60Hz nominal)0.01Hz±0.01%
Dips & Swells
Vrms1/20 ~ 200% of nominal voltage 0.1Vrms±1%
Arms1/21 ~ 3000A1A±1% ±5 counts
1 ~ 300A0.1A±1% ±5 counts
Threshold levels Programmable thresholds in percent of nominal voltage
Event detection based upon ½ cycle rms voltages
Captures Dips, Swells Interruptions and Rapid Voltage Changes
Durationhhh,mm,ss,mmm0.5 cycle1 cycle
Harmonic
Harmonic Order1 ~ 50
Inter-Harmonic Order1 ~ 49
Voltage0.0 ~ 100.0%0.10%±0.1% ± nx0.1%
Current0.0 ~ 100.0%0.10%±0.1% ± nx0.1%
THD0.0 ~ 100.0%0.10%±2.5%
DC Relative0.0 ~ 100.0%0.10%±2%
Frequency0 ~ 3500Hz1Hz1Hz
Phase-360° ~ 0°1°± nx1.5°
Power And Energy
Active Power/Apparent Power/Reactive Power1.0 ~ 20.00MW0.1kW±1.5±10 counts
Energy0.00kWh ~ 200GWh10Wh±1.5±10 counts
Power Factor0 ~ 10.01±0.03
Flicker
Pst(1min),Pst,Plt,PF50.00 ~ 20.000.01±5%
Unbalance
Voltage0.0 ~ 5.0%0.10%±0.5%
Current0.0 ~ 20.0%0.10%±1%
Voltage Phase Angle-360° ~ 0°1°±2digits
Current Phase Angle-360° ~ 0°1°±5digits
Voltage Transient
Vpk±6000Vpk1V±15%
Vrms10 ~ 1000Vrms1V±2.5%
Min. Tested Time50us
Sampling Rate20kS/s
Inrush Current
Arms(AC+DC)0~3000Arms0.1±1% ± 5digits
Inrush Duration6s ~ 32min selectable10ms±20ms
Logger
RecordingParameter, duration time and time interval can be set by user, which can be export on PC
Memory8G
Max. recording time1 year
System Monitor
ParametersVrms,Arms,Harmonic Volts,THD Volts,Plt,Vrms1/2,Arms1/2,Vneg,Hz,dips and swells, unbalance                      
Record Time2h ~ 7days
Record Event Number>10000
LimitsAccording EN50160  or customer definable
General Characteristics
PowerAC220V(1±10%), 50Hz(1±5%), ≤10VA
InterfaceUSB_HOST, LAN
Display5.6' TFT LCD, 320*240
Battery7.4V, 4.4Ah, > 7 hours working time
Dimension & Weight262×173×66mm, 1.6kg