Specifications
used for measuring of the error rate of data communication and for the analysis of line fault and causes2M Transmission Analyzer is a multi-functional and full featured digital transmission system test device, designed for the installation test, engineering check and acceptance, daily maintenance of digital networks, mainly performing channel test, alarm analysis, fault finding and signaling analysis. In addition, this instrument further provides various protocol converters with one-way and bi-directional bit error test function. These capabilities
make it ideal for field use.
Basic Functions
1) 2M measurement
2) Datacom measurement
3) Protocol converter measurement
4) Other functions
Real-time clock
Test pattern: PRBS, Fixed Code and 16-BIT User Word
Error injection: Single and Fixed Rate
Manual and auto-timer measurement
ITU-T G.821, G.826, and M.2100 performance analysis
Main Features
Handheld design and easy-to use
Full-featured measurements to 2M, Datacom
High resolution backlit large LCD screen, with adjustable contrast
Smart navigation mode and multi-languages displays
Extensive error and alarm generation, detection and indication
Histograms analysis of alarm and error events
Up to 99 days continuance test performance
Save/Recall of up to 7 user-defined setups and 70 sets of results
Up to 6 hours operation from a single battery charge
Built-in Li rechargeable battery and smart charger circuit
Can be charged with automobile cigarette lighter battery adapter
Upgradeable software via an integrated RS232C interface
Test results uploaded, conserved and printed by PCManager software
Technical specifications
TX |
| |
Output interface | 75 Ohm balanced, 120 Ohm balanced, conforming to G.703 requirements | |
Signal structure | Unframed Frame (PCM30, PCM31, PCM30CRC, PCM31CRC), conforming to G.704 n×64 Kbit/s structure | |
Line code | HDB3 or AMI | |
Signal rate | 2048 kbit/s | |
Internal clock accuracy | ≤±10ppm | |
Clocking | Internal, external and distill | |
Output intrinsic twittering | <0.05UI(20Hz-100kHz) | |
Test pattern | False random sequence 2E6-1,2E9-1,2E11-1,2E15-1, 2E20-1, 2E23-1, conforming | |
Free TS pattern: | 8bit man mode | |
Code error insertion | FAS ERR once, continuous twice, continuous 3 times, continuous 4 Times BIT ERR single 1E-2~1E-7 | |
Pattern slip | PAT slip | |
RX | ||
Signal input impedance | terminal 75 Ohm unbalanced, 120 Ohm balanced, Tx loss conforms to G.703 bridge 750 Ohm unbalanced,1200 Ohm balanced monitor 20 dB for input sensibility | |
Signal input equalizing feature | 0—9 dB | |
Signal input twittering capacity | conforms to G.823 | |
Input anti-interference | conforms to G.703 | |
Signal structure | Unframed Frame (PCM30, PCM31, PCM30CRC, PCM31CRC), frame signal conforms to G.704 n×64 kbit/s structure | |
Line code | HDB, or AMI | |
Signal rate | 2048 kbit ±50ppm | |
Test pattern | False random sequence 2E6-1,2E9-1,2E11-1,2E15-1, 2E20-1, 2E23-1 conforming to ITU-T0.151, man code 8 bit | |
Frequency test | For line signal and voice channel signal | |
Level test | For line signal and voice channel signal | |
Bit error monitoring | FAS ERR, BIT ERR, CRC-4 code error performance test, CODE ERR | |
Alarm monitoring | AIS, SIG LOSS, RA, MAR, FAS LOSS, CRC LOSS, PAT LOSS, PAT SLIP | |
Slip monitoring | PAT SLIP, CLK SLIP | |
Time delay test | Test time delay performance | |
Bit error analysis | G.821, G.826, M2100 | |
External clock input impedance | Terminal 75 Ohm unbalanced, 120 Ohm balanced, Tx loss conforming to G.703 Bridge 750 Ohm unbalanced,1200 Ohm balanced | |
External clock input signal | HDB3/AMI conforming to G.703, pulse signal,2.5Vp-p
| |
Other Specifications |
| |
BatteryDuration: | 5hs (except Modem status) | |
Dimensions/Weight: | 200mm×160mm×42mm/0.9kg(With battery) | |