    • Delivers the accuracy and measurement performance you need for your application requirements

    • Completely sealed, IP67 rated case for challenging environments

    • Withstands drops up to 10 feet or 3 meters (with holster)

    • Dustproof per IEC60529 IP6x and waterproof per IEC60529 IPx7

    • Meets IEC Overvoltage Electrical Safety Standard No. 61010-1:2001, CAT III, 1000 V, CAT IV, 600 V

    • Features a reversible holster for added protection of the display when not in use

This intrinsically safe multimeter equips you with all the testing and troubleshooting power you need wherever you go, inside or outside IS zones. No need to carry different meters for different areas, or worry about crossing through an Ex-required zone with a non-Ex rated instrument.
The backlit keypad buttons provide extra visibility in poorly lit areas, even when you’re wearing
full PPE. The large display digits and two level bright white backlight also increases visibility. Meter features a long battery life, of up to 400 hours typical without backlight.

Available for sale in the United States and Canada only

What's Included:
Test leads, alligator clips, and three AAA batteries.

Product TypeMultimeter
AC Max (Amps)10
AC Max (Voltage)1000
DC current rangeMaximum amps: 10 A (20 A for 30 seconds maximum)
Amps accuracy: ±(0.2% + 2)
Maximum resolution: 0.01µA
DC voltage rangeMaximum voltage: 1000 V Accuracy: ± (0.05% + 1) Maximum resolution: 10 µV
Diode testerRange: 3 V Resolution: 1 mV Accuracy: ±(2% + 1)
Duty cycleAccuracy: Within ±(0.2% per kHz + 0.1%)
Conductance rangeMaximum conductance: 60.00 nS
Accuracy: ±(1.0% + 10)
Maximum resolution: 0.01 nS
CapacitanceMaximum Capacitance: 9,999 µF Accuracy: ±(1% + 2) Maximum resolution: 0.01 nF
FrequencyMaximum frequency: 200 kHz Accuracy: ±(0.005% + 1) Maximum resolution: 0.01 Hz
ResistanceMaximum Resistance: 50M ohm Accuracy: ±(0.2% + 1) Maximum resolution: 0.1 W
Safety ratingCAT III 1000V, CAT III 600V
Display6000 counts updates 4/sec. 19,999 counts in high-resolution mode
TemperatureOperating Temperature: -20 °C to +55 °C
Storage Temperature: -40 °C to +60 °C
MakeDMMS
ModelFLUKE-28 II EX
Manufacturer numberFLUKE-28II-EX/ETL
BrandFluke