Elenco S-1330 Oscilloscope 30MHz 2-Channel - Delayed Sweep Component Tester, Beam Find, Dual Time Base by Test Equipment Depot

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Test Equipment Depot
781.665.1400


Contact the seller Add to Inquiry Cart

Product Description

  • Dual or single trace operation

  • Calibrated 20-step time base with x10 magnifier

  • AUTO/NORM triggered sweep operation with AC, TV-H, TV-V and line coupling.

  • 1mV/DIV sensitivity

  • Z-modulation

  • Y (CH 2) output

  • Dust cover and 2 free x1, x10 probes included

Specifications
Vertical Amplifiers (CH 1 and CH 2)
Sensitivity5mV-5V/DIV +3% (x1 mode)
1mV/div - 1V/div (6MHz, –3dB) (x5 mode)
Attenuator1-2-5 sequence, 10 step attenuator, plus vernier control.
Rise timeAbout 14ns
Over shootLess than 5%
Input impedance1MΩ +2%, 25pF +10pF
Max. input voltage400V (DC + AC peak)
Operating modesCH 1, CH 2, DUAL (ALT or CHOP) and ADD
Chop frequencyApproximately 500kHz
Algebraic additionCH 1 + CH 2, CH 1 - CH 2
InverterCH 2 only
Horizontal Amplifier
X-Y modeSwitch selectable using X-Y switch, CH 1: X-axis CH 2: Y-axis
AccuracyY-axis ±3% X-axis ±6%
BandwidthDC - 1MHz (–3dB)
X-Y phase differenceApproximately 3° at 50kHz
Sweep System
Sweep display modeMain, Mix, Delay
Hold off time5:1 continuously variable
Main Sweep
Sweep speed0.1μs/div - 0.2s/div in 1-2-5 seq., 20 steps
Accuracy±3%
Variable time control5:1, uncalibrated, continuously variable between steps
Sweep magnification10X, +10%, extend sweep speed up to 10ns/div
Delayed Sweep
Sweep speed0.1μs/div - 0.2s/div in 1-2-5 seq., 20 steps
Sweep magnification10X, +10%, extend sweep speed up to 10ns/div
Accuracy±3%
Delay time positionVariable control to locate desirable waveform for extending
Trigger
Trigger couplingAUTO, NORM, TV-V, TV-H
Trigger sourceCH 1, CH 2, LINE, EXT
Slope±
Trigger Sensitivity
CouplingBandwidthInternalExternal
TV-V20Hz - 1kHz0.5 div0.05Vpp
TV-H1kHz - 100kHz0.5 div0.05Vpp
AUTO100Hz - 30MHz1.5 div0.1Vpp
NORMDC - 30MHz1.5 div0.1Vpp
Component Tester
Test voltageMax. 6Vrms (open circuit)
Test currentMax. 11mA (shorted)
Test frequencyLine frequency
ComponentsCapacitor, inductor, diode, transistor, zener, etc.
CH 2 Output
Output level100mV/div (no load) 50mV/div (50Ω load)
Bandwidth20Hz - 30MHz (–3dB)
Other Specifications
CRT
TypeRectangular with internal graticule
Adjustable graticule illumination
Display area8 x 10 div (1 div = 1 cm)
Accelerating voltage:2.1kV
PhosphorP31
Z modulationPositive TTL signal, low level blank intensity at any intensity,
high level unblank any intensity.
Trace rotationAdjustable front panel
CalibratorSquare wave 1kHz, 2Vpp +3%
Power requirements115, 230VAC +10%, 50/60Hz
Power consumptionApproximately 40 watts
Dimensions5 1/4” (H) x 12 3/4” (W) x 15 5/8” (D)
Net weight18 lbs. 12 oz. (7.6kgs.)


Item added to Inquiry Cart

Continue shopping Go to Inquiry Cart