AEMC L404 Event Logger by Test Equipment Depot
- Item Condition:
- Brand:
- Model#:
- Location:
- Price:
Product Description
Four input channels
Works with dry contact closure or 0-3 and 0-5VDC logic levels
Programmable storage rates from 8 every second to 1 every day
Stores up to 50,000 measurements in non-volatile memory
Powered by standard Alkaline batteries
Lightweight, compact, fits anywhere
5 LED indicators quickly and clearly display logger status
Includes DataView software for data storage, real-time waveform display, analysis and report generation
Isolated USB communication cable and batteries included
EN 61010-1; 50V CAT III
| AEMC L404 Specification | |
| Electrical | |
| Channels | Four |
| Input Connection | One 8 position removable screw type terminal block |
| Voltage Range | 0 to 5Vdc or contact closure |
| Sample Rate | Selectable from 125mS to 1 day |
| Storage Rate | Event triggered |
| Storage Modes | Event logging |
| Recording Length | 15 minutes to 8 weeks, programmable using DataView |
| Memory | 50,000 events (512KB) The recorded data is stored in non-volatile memory and retained even if the battery is low or removed. |
| Communication | USB 2.0 optically isolated |
| Power Source | 2 x 1.5V AA-cell Alkaline batteries |
| Battery Life | 100 hours to >45 days (dependent on storage rate/recording length) |
| Mechanical | |
| Dimensions | 4.94 x 2.75 x 1.28" (125 x 70 x 32mm) |
| Weight (with battery) | 6.4 oz (180 grams) |
| Case | UL94-V0 |
| Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) |
| Shock | IEC 68-2-27 (30G) |
| Drop | IEC 68-2-32 (1m) |
| Environmental | |
| Operating Temp. | 14° to 122°F (-10° to 50°C) |
| Storage Temp. | -4° to 140°F (-20° to 60°C) |