Agilent/HP 8562A 1 khz-22 GHz Spectrum Analyzer by US Instrument Services
- Item Condition:
- Brand:
- Model#:
- Location:
- Price:
Product Description
The Agilent/HP 8562A spectrum analyzer puts high performance, synthesized technology into a lightweight, portable package. Ruggedized to military specifications, this analyzer is engineered to survive harsh field conditions. This unit performs a wide variety of jobs from communication system and component testing to radar and millimeter measurements.
The Agilent/HP 8562A extends the features and capabilities of the RF members of the HP 8560 series into the microwave frequency range. In addition, the 8562A has standard, preselected frequency ranges of 9 kHz to 22 GHz that can be extended to 26.5 GHz with option 026. Its internal preselector requires no adjustment after 30 minutes at room temperature. This means faster measurements, which can be especially important in automated testing. For millimeter-wave measurements, preselection can be extended to 75 GHz using the HP 11974 series millimeter mixers. Unpreselected frequency range can be extended to 110 GHz using the HP 11970A series mixers and to 325 GHz using mixers from other manufacturers.
Features
Frequency Range: 1 kHz to 22 GHz
Counter Resolution: 10 Hz - 1MHz (selectable)
Frequency Span
Range: 0 Hz-2.5kHz x NResolution Bandwidth (-3 dB)
Range: 100 Hz - 1MHz in a 1, 3, 10 sequence and 2 MHzVideo Bandwidth
Range: 1 Hz - 3 MHz in a 1, 3, 10 sequenceAmplitude Range: +30 dBm to displayed average noise level
Reference Level Range: Log, -120 to +30 dBm in 0.1 dB steps
Displayed Average Noise Level:
-120 dBm, 1 MHz to 2.9 GHz
-121 dBm, 2.75 GHz to 6.46 GHz
-110 dBm, 5.86 GHz to 13.0 GHz
-105 dBm, 12.4 GHz to 19.7 GHz
-100 dBm, 19.1 GHz to 22.0 GHzAmplitude Accuracy
Frequency Response (flatness)
Frequency Range:
1 kHz - 2.9 GHz, ±1.0 dB
2.75 - 6.46 GHz, ±1.5 dB
5.86 - 13.0 GHz, ±2.0 dB
12.4 - 22.0 GHz, ±3.0 dBDemodulation Modulation Type: AM and FM