Specifications
A/C cooling & hot water;
high efficiency & energy saving;
safe operation & control;
easy installation & maintenance;
This CAM series Air / water heat pump for heating unit can connect to indoor fan coil unit for house cooling in summer and house heating in winter; sanitary hot water produced all year around.
More models of Air / water heat pump for heating series(some models not listed, if you have heating capacity enquiry for other data, kindly check with us):
CAM-12XB
CAM-16XB
CAM-20XB
CAM-24XB
CAM-28XB
CAM-40XB
CAM-60XB
CAM-80XB
CAM-100XB
Each project has its special requirement for installation, if any queries, our engineer will be so glad to make any drawing or suggestion for you! Pls kindly contact us!
Technical Parameters:
Website:www.clitechchina.en.alibaba.com
Word: Air / water heat pump for heating
| Model | CAM-100 |
| AC cooling | Cooling capacity kW | 66.2 |
| AC Water flow M³/H | 11.39 |
| Input power KW | 22.4 |
| Rated input current A | 41 |
| EER | 2.96 |
| AC cooling with heat recovery for hot water | Cooling capacity kW | 69.3 |
| AC Water flow M³/H | 10.53 |
| Heating capacity kW | 77.6 |
| Hot water output T/H | 1.7 |
| Input power KW | 17.3 |
| Rated input current A | 32 |
| EER+COP | 8.02 |
| AC heating with Hot water | Heating capacity kW | 90.00 |
| Hot water output T/H | 1.94 |
| Input power KW | 18.66 |
| Rated input current A | 34.87 |
| COP | 4.82 |
| Rated & Max water temp °C | 55°C and 60°C |
| Power source V/PH/HZ | 380V/3N/50HZ |
| Noise level dB(A) | <60 |
| Unit size W x D x H mm | 2205*1030*2090 |
| Wood Packing W x D x H mm | 2300*1140*2260 |
| Net weight Kg | 930 |
| Throttle Type | Electronic expansion valve/Thermal expansion valve |
| Refrigerant Qty kg | 6*4 |
| Sanyo Compressor Pcs | 4 |
| Protection | Built-in protection as overheating protection, sequence protection, undervoltage protection, time-delay start protection etc |
| Condensor | Heat exchanger type | Finned tube heat exchanger |
| Qty pcs | 1 |
| Fan type | Axial big twist angle fan |
| Motor KW | 1.5 |
| Hot water | Heat exchanger type | Axial big twist angle fan |
| Qty pcs | 1 |
| Water flow M³/H | 15.48 |
| Pressure Loss KPa | 48 |
| Pipe size mm | 50 |
| Air Conditioner | Heat exchanger type | Axial big twist angle fan |
| Quantity | 1 |
| water flow M³/H | 10.53 |
| Pressure Loss Kpa | 47 |
| Pipe size mm | 50 |
| Water side max working temp kPa | 1000 |
| 1.Rated cooling working condition: Air source side inlet water temp is 35°C, AC side inlet water temp is 12°C, outlet water temp is 7°C |
| 2.Rated heating&hot water condition: Air source side DB/WB is 20°C/15°C,initial hot water temp 15°C, ending hot water temp 55°C;AC side inlet water temp 40°C,outlet water temp 45°C. |
| 3.Rated cooling&hot water working condition: initial hot water temp 15°C,ending hot water temp 55°C;AC side inlet water temp 12°C,outlet water temp 7°C. |